Product Search
Keyword:
    Product List      
   Mini Circuit Breaker
   Earth Leakage Circuit Breaker
  Moulded Case Circuit Breaker
   AC Contactor
   Relay
   Fuse
   Meter
   Switch
   Tool
   Lighting
   Stabilizer
   Distribution Box
   Wire Accessories
   Industrial Plug-Socket
   Wire-Cable
   Pushbutton And Indicator
 
Products Home_Current Location_Products
ESM3E MCCB

Application

     ESM3E MCCB is simple and universal solution to fit all the needs in terms of low voltage protection.

 

Specifications

Type

ESM3E-100F

ESM3E-100N

Number of Pole                     In            at 40

3

1

3-4

Rated Current(A)

15,16,20,25,
30,32,40,45,
50,60,63,75,
80,100

15,16,20,25,
30,32,40,45,
50,60,63,75,
80,100

15,16,20,25,
30,32,40,45,
50,60,63,75,
80,100

Rated Insulating Voltage(V)         Ui

690

690

690

Rated Impulse Withstand Voltage (kv)Uimp

6

6

6

Rated Operational Voltage(V)       Ue

AC 50/60Hz

550

415

550

DC

250

125

250

Electrical Characteristics as Per IEC 60947-2,EN60947-2, JISC8201-2-1

Ultimate Breaking IcCapacity(kA rms)

AC 50/60Hz       110/130V

25

25

25

                          220V/230V/240V

25

18

25

                          380V

10

2.5

18

                            400/415V

10

2.5

15

                            400V

7.5

-

10

                            550V

5

-

5

DC                      215V(1P)

5

5

5

                           250V
                        
2P in series

5

-

5

Rated Service Breaking             Ics
Capacity (kArms)

%Lcu                 110-400V

50%

50%

50%

                          415-550V

50%

50%

50%

Suitability for Isolation

Utilisation Category

A

A

A

Pollution Degree

3

3

3

Endurance(C-0 cycles)

Mechanical

8500

8500

8500

Electrical  In/415V

1500

1500

1500

 

Type

ESM3E-250F

ESM3E-250N

ESM3E-400N

ESM3E-400H

Number of Pole                     In   at 40        

3

3

3-4

3-4

Rated Current(A)

100,125,
150160,
175,200,
225,250

100,125,
150160,
175,200,
225,250

250,300,
320,350,
400

250,300,
320,350,
400

Rated Insulating Voltage(V)         Ui

690

690

690

690

Rated Impulse Withstand Voltage (kv)Uimp

6

6

8

8

Rated Operational Voltage(V)       Ue

AC 50/60Hz

550

550

550

550

DC

250

250

250

250

Electrical Characteristics as Per IEC 60947-2,EN60947-2, JISC8201-2-1

Ultimate Breaking IcCapacity(kA rms)

AC 50/60Hz       110/130V

25

50

-

-

                          220V/230V/240V

25

50

85

100

                            380V

18

25

36

50

                            400/415V

18

25

36

50

                            400V

15

20

36

50

                            550V

5

8

15

20

DC                      215V(1P)

5

20

-

-

                           250V
                        
2P in series

5

20

20

40

Rated Service Breaking             Ics
Capacity (kArms)

%Lcu                 110-400V

50%

50%

50%

50%

                          415-550V

50%

50%

-

-

Suitability for Isolation

Utilisation Category

A

A

A

A

Pollution Degree

3

3

3

3

Endurance(C-0 cycles)

Mechanical

10000

10000

4000

4000

Electrical  In/415V

5000

5000

1000

1000



 


Published:2013-10-23   【Print this page】 【Close the window】【products】  Browse:380 Secondary

 

 