Analogue Panel Meter 1

 

Model: PM-96A PM-72A PM-48A
Accuracy: Class 1.5
Specification: 0.1A, 0.5A , 1A, 1.5A , 3A,
5A, 7.5A, 10A, 15A, 20A, 25A, 30A,
40A. 50A 60A, 75A, 100A
For 5A~10KA use external current
transformer with secondary current 5A and 1A.

 

 

 

 

  

Model: 90° :PM-F96 PM-F72 PM-F48
           24° :PM-F96 PM-F72 PM-F48

Accuracy:Class1.5

Voltage:50V,100V,220V,380V,440V,415V

Frequency:45~55Hz, 45~65Hz,55~66Hz,
47~53Hz,57~63Hz,44~56Hz,54~66Hz,
450~550Hz,450~650Hz,550~650Hz

 

  

Wattmeter Model 90° :PM-W96 PM-W72
PM-W48
Varmeter Model 90°: PM-Var96 PM-Var80
PM-Var72 PM-Var48
Accuracy:Class 2.5
Single phase:100V 220V 380V
Three Phase
100V 220V 380V
                       415V
Three Phase
100V 220V 380V
                       240V
415V
About-mentioned can be connected directly
The following should be connected with voltage
transformers:380/100V 500/100V 3K/100V
6K/100V 10K/100V 35K/100V...
Current:1A,5A

 

  

Model:PM-AM96 PM-AM72
For measuring average maxinum value
when it is 8 min or 15min or 30min,
Accuracy:class 3.0

 

  

Model: PM-Z96A PM-Z72A
The instrument are suitable for measuring AC
Voltage in Three phase 4 or 3 wrie networks
by using changeover switch on the front side
of the instrument.
Movemenmt: Moving-iron movement Wrth oil
filled bearings, practically vibration-free oil
damping
Accuracy: Class 1.5
Frequency: 50Hz
3 phase 4 wire measuring range:
60/100V 801150V 100/200V 150/250V
250/400V 300/500V
3 phase 3 wire measuring range:
100V 150V 200V 250V 400V 500V

 

  

Model: PM-%V PM-72V PM-48V

Accuracy: Class 1.5
Spectfication: 30V, 50V, 75/. 100V, 120V,
150V 200V 252V 400V 450V. 500V.
600V, 450V-450KV ,
Meters can use potential transformer with
seoondaryvottage 100V

 

  

Model 90° : PM-PF96 PM-PF72
           240°: PM-PF96 PM-PF72 PM-PF48

Accuracy: Class 2.5

Voltage:100V,220V,380V,415V/
current 1A or 5A

Spectfication:0.5cap-1-0.5ind 0.3cap-1-0.4ind
0.7cap-1-0.2ind

 

  

Model:P M-E96A PM-E72A
Accuracy:Class 1.5
Specification: AC 100mA lA 3A 5A
For 10A-10KA meters have to use external
transformer with secondary current 1A,15A
Frequency:50/60Hz
Consumption:0.2VA

 

  

Model: PM-2M96 PM-2M72
Accuracy: Class 3.0(i nstantanous values)
                Class 1.5
For measuring average maximum current
value and instantaneous values for combined
with moving iron movement meters.

 

  

Model: 90" PM-2T96V
Accuracy:class 1.5
Specification : 30V 50V75V 100V 120V 150V
200V 250V 450V 500V 600V for 450-450kV,
Meters can use ’potential transformer with
seoondaryvottage 100V or 110V

 

  

Mcdel:PM-H96 PM-H72 PM-H48
Display:99999.9
Voltage:AC 100-125V AC200-250V
            AC380V-440V AC 24V
Burden: 2.5VA
Frequency:50/60Hz
Features:
Elapsed time meters or hours run
meters monitor ON/RUN time of plant.

 

  

Model:PM-R96 PM-R72
Accuracy: Class 0.5
Voltage: 50V 100V 220V 380V 440V 415V
Frequency: 45-55Hz 45-65Hz 55-65Hz
47-53Hz 57-63Hz 44-56Hz 450-550Hz
450-650Hz 550-650Hz
This vibrating reed frequency meter wth one
row of horizontal reeds or with two rows of
horizontally arranged reeds for connection to
one main voltage, vertical arrangements on
request.

 

  

Model: PM-AM96 PM-AM72S
For the control of maximum demand and control
of overload on distribution systems, constructed
with an electronic circuit and 5A relay, The alarm
was set by the blue slim pointer, the red light is the
alarm one. Which can be used with buzzer
Accuracy: class 3.0
Rating: 1A, 5A for use with separate CT
Frequency: 50160Hz
Overload:1.2 continuos, 10X1 second via 5/5 CT
Auxiliary: AC 220V ± 10% 50Hz Burden:2.6V/A
Time delay: 1 second opproxi mately Ned
Working range:20-100% ± 10%

 

  

Model :PM-2R96
Accuracy: Class 0.5
Voltage: 50V 100V 220V 380V 440V 415V
Frequency: 45~55Hz 45~65Hz 55~65Hz
47~53Hz 57~63Hz 44~56Hz 450~550Hz
450~650Hz 550~650Hz
This vibrating reed frequency meter with one
row of horizontal reeds or wfth two rows of
horizontally arranged reeds for connection to
one main voltage, vertical arrangements on
request.

 